Workstation Agent
79643: The Agent now runs on .NET 10 and, on Linux, requires glibc 2.27 or later, such as Ubuntu 18.04 or later.
81104: Fixed an issue where unplugging a dongle, or reconnecting or restarting the Agent, replaced a dongle's name and serial number with a generic device name and ID in Dongle Monitoring.
61238, 81104: Fixed an issue where the Agent didn't identify Vector dongles.
81104: Improved accuracy of dongle names and serial numbers when several dongles are plugged in.
81104: Fixed an issue where dongle monitoring didn't start when the Agent started without a connection to Agents Hub.
67425: Fixed an issue where the Agent failed to release AutoCAD when the open drawing was in a folder listed under Banned Directories. The Agent now closes the drawing without saving it and exits AutoCAD.
80415: Fixed an issue where the number of open handles used by the Agent grew for as long as it ran.
79643: Fixed an issue where an upgrade failed to start the Agent Updater service when that service was stopped.
71537: Fixed an issue where Save and Close didn't close GT-SUITE or free its license.
78672: Fixed an issue where Force project selection closed an application without a notification when another project prompt had appeared in the previous 30 seconds. It now notifies you and opens Personal Dashboard every time.
81104: Log files now roll over at 50 MB instead of growing to 1 GB. The Agent keeps at most 30 main log files and 10 for each area log, which you can change in settings.json.
76974: The Agent now reports each workstation's operating system, OS version, and whether it runs on a virtual machine to Agents Hub.
78465: The Windows Agent can now report software installs and uninstalls as they happen, with the time each change was seen, so short-lived installs between inventory scans are no longer missed. Reporting is turned off by default.
78986: Fixed an issue where the macOS Agent restarted in a loop and reported no data when it could not read the Chrome profile folder.
78672: Fixed an issue where Force project selection closed an application opened without an active project but showed no notification and did not open Personal Dashboard to pick a project.
79573, 79577: The Agent now reads the Autodesk cloud username for Advance Steel as well as AutoCAD and AutoCAD LT, and an unresponsive Autodesk licensing service no longer stalls process monitoring.
79573: When several users sign in to the same workstation under one OS account, each Agent stays connected and a release reaches only the Agent in the user's own session.
65897: Fixed an issue where the Agent did not pick up changes to a project environment variable after the initial read.
78294: Fixed an issue where the installer did not detect SolidWorks 2026, so the SolidWorks checkbox stayed greyed out and the extension was never installed, leaving the Agent with no SolidWorks monitoring.
73668, 73669, 74895: The Agent now sends a periodic snapshot of every process it currently sees running, and signals when it has finished replaying data it buffered while offline. Process Manager uses both to close rows left open by an agent that crashed or went offline, so Active Processes no longer keeps stale entries.
76426: Fixed an issue in the Workstation Agent installer where the "Check for connectivity" test could fail when connecting to Agents Hub, even when the address was correct.
75294: Fixed an issue where the Workstation Agent kept sending Dongle Monitoring and Web-Monitoring requests to Agents Hub even when those features were turned off.
75100: Added an uninstall script for the Linux Agent that cleanly removes the service, desktop entry, and installation directory.
75056: Fixed an issue where a process resumed from suspension while the workstation was idle inherited the accumulated idle time instead of starting from zero, which could immediately re-suspend it.
75494: Fixed an issue where stopping the Agent service on Linux or macOS hung for about 90 seconds and ended in a forced kill instead of a clean shutdown.
75534: Fixed an issue where re-running the macOS installer to upgrade the Agent left it stopped until the next login.
75021: The Agent now includes each monitored process's command line in monitoring data, so Process Manager release exclusions can match on command-line arguments.
74341: The Workstation Agent now supports OpenLM Platform's enhanced cloud authentication by sending the required X-CSRF security header. Upgrade to this version or later to keep agents connected — earlier versions can no longer connect to OpenLM Platform in the cloud and stop reporting data until upgraded. Agents can be mass-upgraded from Agent Activity Manager.
53462: Workstation Agent now runs on macOS (Intel and Apple Silicon), installable interactively with the .pkg or shell installer or across a fleet with MDM.
74790: Fixed an issue where the Workstation Agent was not added to /Applications after installation on macOS.
74349: On Linux and macOS, the Workstation Agent now minimizes an application window before suspending the process, matching the existing Windows behavior.
69235: Updated the initial installer seed mechanism.
58109: Reworked the Workstation Agent monitoring sequence.
69269: Workstation Agent now supports encrypted Client Authorization files, so sensitive credentials are no longer stored in plain text.
63019: Fixed a Linux installer issue affecting Network Users.
70443: Fixed an issue where Workstation Agent stopped unexpectedly after a restart.
70635: Fixed an issue where the AutoCAD extension named pipe server failed to initialize on AutoCAD 2025 (.NET 8).
70639: Fixed an issue where TouchPointEvent.Enrich() overwrote the Workstation field with the UserName instead of the HostName.
71453: Fixed excessive log file growth on specific user terminals.
72154: Fixed an issue where Workstation Agent did not start automatically after an auto-upgrade.
73177: Fixed an issue where dongle and process usage was not displayed because the offline monitoring and process-user features were missing from the feature allowlist.
70516: Removed the AutoCAD plugin from the Platform Workstation Agent. The plugin now ships separately.
70517: Deleted the AutoCAD plugin projects and solution file from the Workstation Agent codebase.
57021: Agents no longer produce project-related notifications when the projects configuration is disabled in Agents Hub.
67510: OpenLM Platform Workstation Agent can now run either elevated or non-elevated based on the permissions.runAsElevated setting, showing a User Access Control (UAC) prompt only when enabled.
64672: Process Manager now supports command-line launch arguments and window title monitoring.
61308: Added an automatic mass update mechanism for Workstation Agent.
68556: Fixed an issue where Workstation Agent process is terminated after an upgrade and fails to start again.
66546: Fixed an issue where the Installer did not show the Use Dongle Monitoring checkbox in Cloud mode.
66129: Fixed an error in Agents Hub that could show "Product not activated" when Dongle Monitoring is off.
65897: Fixed an issue where Workstation Agent did not pick up changes to a project environment variable after the initial read.
67302: Improved End-User Services project handling.
62604: Dongle Monitoring communication now uses WebSockets instead of HTTP.
64994: Resolved an issue where dongle sessions were not recreated after a computer resumed from sleep.
65290: When installed under the SYSTEM account (e.g., via SCCM), Workstation Agent now automatically starts under the logged-in interactive user.