Skip to main content

AbsInt

OpenLM can monitor the AbsInt License Manager (ALM), which serves the license tokens of AbsInt tools such as Astrée and RuleChecker, through OpenLM Broker. Broker supports it with the AbsInt LM Type and reports it to OpenLM SLM in the OpenLM Generic format.

Broker reads the token usage and the connected users from the ALM web interface, and reports each token type as a feature, with the users who hold its tokens, to OpenLM SLM.

Requirements​

  1. OpenLM SLM or Software License Management Cloud (SLMC) environment with permissions to approve new OpenLM Generic license managers.
  2. OpenLM Broker v24.11.11.806 or higher installed on a machine that reaches the ALM web interface over HTTP. In Broker versions earlier than v25.2.6.1326, the default address of the data inquiry is http://localhost:8080/?xml instead of your ALM, and you correct it in OpenLM Broker configuration.
  3. Network access from the Broker to OpenLM SLM (default port 5015).
  4. The host name of the machine that runs the ALM, and the HTTP port of its web interface: 42425 by default. Don't use the ports that AbsInt tools use to request tokens, 42426 (TLS) and 42424 (legacy tools). See the Astrée and RuleChecker 23.10 release notes for the default ports.
  5. The HTTP web interface of the ALM turned on. It is on by default. An ALM started with --http-port 0 serves no HTTP web interface.
  6. A firewall rule that lets the Broker machine reach the ALM host on the web interface port.

Monitoring capabilities​

LM typeCommandsLogsQuantityExpiration dateDeniedBorrowingAllocationsReport resolution
AbsIntYesNoYesYesNoNoNoMinutes

For each token type that the ALM serves, Broker reports:

  • Feature name: the program name and the token name, joined with a dot, for example a3c.astree or a3c.rulechecker-connections. OpenLM SLM shows the same name as the product.
  • License total and licenses in use: the total and the assigned tokens of the type, as the Token usage tab of the ALM web interface shows them.
  • Expiration date: the expiration date of the license installed in the ALM. The same date applies to every token type.
  • License type: Broker reports every token type as Floating.
  • Vendor: AbsInt, unless you add a vendor on the Vendors tab.

For each client connection that holds tokens, Broker reports the user and the computer that the ALM lists for the connection, and the number of tokens that it holds of each type. A connection that holds no tokens doesn't appear in OpenLM SLM.

The ALM doesn't report when a session started. In OpenLM SLM, a session starts at the first query that finds it.

Broker does not report denials, borrowed licenses, or license allocations. It runs no commands that start or stop the ALM.

How OpenLM interfaces with AbsInt​

The following diagram shows how OpenLM Broker collects AbsInt usage and sends it to OpenLM SLM.

Diagram: OpenLM Broker on the Broker machine reads the token usage and the connected users from the AbsInt License Manager web interface over HTTP on port 42425, and sends license data to OpenLM SLM, which you manage in the EasyAdmin web application. How OpenLM Broker collects AbsInt usage.

Broker queries the ALM web interface every 55 seconds by default. Broker reads no ALM log file and no license file.

Each query reads the current state of the ALM. A session that starts and ends between two queries doesn't reach OpenLM SLM, and Broker does not upload the usage history from before you add the license manager.

The pending entry in EasyAdmin gets the time zone of the Broker machine.

OpenLM Broker configuration​

Note

Install OpenLM Broker and confirm that it reports to OpenLM SLM before starting these steps.

  1. Open a browser on the Broker machine and go to the Broker web UI at http://localhost:5090/.

  2. On the License Managers page, check that Host shows the host name of the ALM machine.

    OpenLM SLM lists the license server under this host name. The field holds the host for every license manager on the page, not for AbsInt alone.

    • If the field is empty, enter the host name of the ALM machine and select the save icon next to the field.
    • If it names a different machine, leave it as it is, and enter the ALM host name in the data inquiry address in step 5.
  3. Select Add License Manager and select AbsInt as the LM Type.

  4. In Port, enter the HTTP port of the ALM web interface, for example 42425. Then select Add.

    OpenLM SLM names the license server after this port, as 42425@<host>.

    The Add License Manager dialog with LM Type set to AbsInt and port 42425 Add AbsInt as the license type.

  5. On the Commands tab, check the address in the Data Inquiry box.

    Data Inquiry is the only command for AbsInt. It runs every 55 seconds by default, set in Watch interval (sec). Its address holds the Host and the port that you entered, for example http://absint01.example.com:42425/?xml.

    • If the ALM runs on the machine in Host, keep the address.
    • If the ALM runs on another machine, replace the host name and the port in the address with those of the ALM, for example http://alm01.example.com:42425/?xml.
    • If the Broker is earlier than v25.2.6.1326, the address is http://localhost:8080/?xml. Replace it with the ALM host name and port. Restore Default brings back the wrong address in these versions.

    Keep /?xml at the end of the address. Without it, the ALM returns its web page, and Broker cannot read the token usage.

    The Commands tab of the AbsInt license manager with the periodic Data Inquiry command, a 55-second watch interval, and the address http://absint01.example.com:42425/?xml Check the Data Inquiry address.

  6. Leave Use the operating system start/stop commands off and the Log Files tab empty.

  7. (Optional) On the Vendors tab, add a vendor to show a vendor name other than AbsInt in OpenLM SLM.

  8. Select Save.

To test the address, open the AbsInt license manager again, select Data Inquiry on the Commands tab, and select Execute. A working address returns each token type with its total and the users who hold tokens. If you never saved the license manager, Broker answers "Need to save first in order to execute command".

The Execution Result of the AbsInt Data Inquiry: the four token types of absint01.example.com with their totals and the tokens in use, and the users mjones on ws-1001 and asmith on ws-1002 Test the address with Execute.

Detect doesn't find the ALM. Add the license manager by hand.

To read the ALM over HTTPS, use https:// and the HTTPS port of the web interface, 42427 by default, in the Data Inquiry address, for example https://alm01.example.com:42427/?xml. On a Windows Broker machine, Broker trusts the certificates in Trusted Root Certification Authorities of the local computer. Import the ALM certificate there, or the certificate of the authority that issued it, and restart the OpenLM Broker service. Otherwise Execute answers with an error that starts with PKIX path building failed.

OpenLM SLM configuration​

Automatic configuration through EasyAdmin​

When the Broker reports AbsInt, approve the license server in EasyAdmin:

  1. Open EasyAdmin (http://<Server IP>:5015) and go to Start → Widgets → License Manager - Servers.

  2. Select the There are N servers pending approval link at the top of the widget.

    The License Manager - Servers widget with the link There are 5 servers pending approval at the top Pending approval message.

    The Administration - License Manager Servers window opens, with the pending entries at the top of the list.

  3. Find the pending AbsInt entry, with the host name and the port as configured in Broker, and select the edit icon at the end of its row.

    The entry has the Status Pending and the Display Name <port>@<host>. OpenLM SLM has no plugin for the AbsInt type, so its Type is OpenLM Generic, the protocol that Broker reports it with. The edit icon appears when you hover over the row.

    The Administration - License Manager Servers window with the pending AbsInt entry 42425@absint01.example.com, Type OpenLM Generic, Source Broker, and the edit icon at the end of the row Approve the pending license server.

  4. Update the Display name to something meaningful, confirm the Host Name and Port, and select APPROVE.

    Use Broker is on, and Time Zone is the time zone of the Broker machine.

    The PENDING LICENSE MANAGER page with Display name 42425@absint01.example.com, Type OpenLM Generic, Use Broker on, the host name, port 42425, the time zone of the Broker machine, and the APPROVE button Update the display name and approve.

Manual configuration through EasyAdmin​

If automatic configuration fails:

  1. Go to Start → Administration → License Manager Servers.

  2. Select Add LM.

  3. In Display name, enter a name for the connection, for example AbsInt.

  4. From Type, select OpenLM Generic.

    Use Broker turns on.

  5. In the row under Host Name, Port, and Time Zone, enter the host name and the port exactly as configured in Broker for AbsInt, and select the time zone of the Broker machine.

  6. Select SAVE.

The Time Zone of the entry must match the time zone of the Broker machine. When the two differ, the license server doesn't show as Up to date.

Verify your configuration​

  1. Open EasyAdmin in your browser.

  2. Go to Start → Widgets → License Manager - Servers.

  3. Find the AbsInt license server and confirm that its Status is Up to date.

    After approval, the license manager appears with the Type OpenLM Generic. Quantity is the sum of the totals of all token types, and Used is the number of tokens in use.

    The License Manager - Servers widget with the AbsInt license server, Status Up to date, Type OpenLM Generic, Quantity 115, and Used 5 The license manager appears as OpenLM Generic.

  4. In the row of the AbsInt license server, select the number in Quantity.

    The Licenses window opens with 1 row for each token type, with Vendor AbsInt, License Type Floating, its total in Total, and the tokens in use in Used. Compare them with the Token usage tab of the ALM web interface.

    The Licenses window with the 4 token types of the AbsInt license server, Vendor AbsInt, License Type Floating, their totals and their Used counts AbsInt token types in the Licenses window.

  5. Select a token type's number in Used to confirm that sessions arrived.

    The Currently Consumed Licenses window opens. It lists the open sessions of all license servers, so the AbsInt sessions can be on a later page. Each client connection that holds tokens appears with its username, Workstation, and Start Time, and Consumed Tokens shows how many tokens of the type it holds. Compare them with the Connected clients tab of the ALM web interface.

    The Currently Consumed Licenses window with 4 AbsInt sessions: mjones on ws-1001 holding 2 a3c.astree tokens and 1 a3c.astree-connections token, and asmith on ws-1002 holding 1 a3c.rulechecker token and 1 a3c.rulechecker-connections token AbsInt sessions in Currently Consumed Licenses.

Troubleshooting​

The Broker log holds the detail for each of these problems, in the logs folder of the Broker installation. The periodic data inquiry writes to port-<port>-AbsInt.log, and Execute writes to broker-service.log.

If AbsInt never appears as pending in EasyAdmin, confirm that the Broker reports to OpenLM SLM: other license managers on the same Broker update in EasyAdmin.

If the license server shows Data error with the message Parsing failed. Data format is wrong. Can't convert xml., check whether a client is connected to the ALM. When no client is connected, OpenLM SLM shows Data error and Used drops to 0. The status returns at the first query after a client connects.

If the license server keeps old data, Broker cannot read the ALM and sends no data. To see the cause, open the AbsInt license manager in the Broker UI, select Data Inquiry on the Commands tab, and select Execute. Then check the following:

  • The address ends in /?xml. Without it, the ALM returns its web page.
  • The address opens in a browser on the Broker machine. If it doesn't, check the host name, the port (42425 by default, not 42424 or 42426), the firewall between Broker and the ALM host, and that the ALM runs and was not started with --http-port 0.
  • For an https:// address, the Broker machine trusts the ALM certificate.

Known limitations​

  • Broker does not report denials, borrowed licenses, or license allocations, and does not upload usage history. Broker doesn't import the past token usage that the ALM web interface shows.
  • Broker reads the current state of the ALM, so it can miss a session shorter than the watch interval. A session in OpenLM SLM starts at the first query that finds it, not when the user started the AbsInt tool.
  • When no client is connected to the ALM, OpenLM SLM shows Data error for the license server, and Used drops to 0.
  • When Broker cannot read the ALM, OpenLM SLM keeps showing the last status and counts of the license server.
  • ALM user accounts, which the Manage users tab of the ALM defines for password-protected access, are not reported.
  • Broker runs no commands for the ALM. It cannot start or stop the ALM.